Engrove Audio Tools · Cartridge database reference
Nagaoka MP-100
Nagaoka MP-100 cartridge reference data for tonearm matching, compliance, tracking force and resonance setup.
Reference specifications
| Manufacturer | Nagaoka |
|---|---|
| Model | MP-100 |
| Type | Moving Iron |
| Body mass | 6.5 g |
| Compliance at 10 Hz | 8.5 CU |
| Compliance source | estimated |
| Tracking force | 2.05 g recommended |
Setup context
Use this cartridge reference with the Tonearm Match Lab to estimate cartridge-tonearm resonance. The key setup inputs are body mass, tracking force and 10 Hz compliance.
Reference data is best-effort and should be checked against manufacturer documentation before critical setup decisions.
Related Nagaoka cartridges
Model-specific matching analysis
Its 6.5 g body mass is included in every total moving-mass estimate below. The calculation uses 8.5 CU at 10 Hz; this value dominates how strongly resonance shifts with tonearm mass. The stored tracking-force reference is 2 g. The database classifies this cartridge as Moving Iron.
| Tonearm effective mass | Estimated total mass | Calculated resonance | Interpretation |
|---|---|---|---|
| 6 g tonearm | 13 g | 15.14 Hz | above the usual 8–12 Hz setup window |
| 10 g tonearm | 17 g | 13.24 Hz | above the usual 8–12 Hz setup window |
| 14 g tonearm | 21 g | 11.91 Hz | inside the usual 8–12 Hz setup window |
| 20 g tonearm | 27 g | 10.51 Hz | inside the usual 8–12 Hz setup window |
| 25 g tonearm | 32 g | 9.65 Hz | inside the usual 8–12 Hz setup window |
Calculation: f = 1000 / (2π√(M×C)), using cartridge mass, 0.5 g fasteners and the stated 10 Hz compliance. This is a setup estimate, not a laboratory measurement.
Data provenance
Research match: src/data/audio/v3/runtime/cartridges.index.json.
No public source URL is stored for this reviewed record.